SWRO system 2 m3/h

APPLICATIONS

Desalination units for operations requiring a reliable source of fresh water: boutique coastal hotels, eco-resorts, coastal farms, greenhouses, coastal construction site, small islands, science coastal camps

YWT SWRO System 2 m³/h is an industrial seawater reverse osmosis system designed for reliable and efficient desalination. Built with high quality components and automated process control, it provides consistent freshwater production for industrial, commercial and professional water treatment applications.

Download PDF

Reliable Company

A stable company with extensive experience in the water industry.

High-Quality Products

We develop high-quality products at competitive prices.

Professional Expertise

Delivering advanced solutions backed by knowledge, innovation, and industry expertise.

Parameters

PHYSICAL PARAMETERS

Approximate dimensions (bare): 2.1 × 1.0 × 1.90 m
Approximate dimensions (crated): 2.30 × 1.20 × 2.0 m
Dimensions: Width × Depth × Height, ±5%
Approximate weight (bare): 350 kg
Approximate weight (crated): 460 kg
Maximum Power Consumption: 11,530 W

CONNECTION PORT SIZES

Inlet water: G 1½″
Permeate: G 1½″
Concentrate: G 1″
CIP inlet: G 1½″
CIP return: G 1½″
CIP permeate: G 1½″
Antiscalant dosing port: G ½″

 

YWT SWRO System 2 m³/h

is an industrial seawater reverse osmosis system designed for reliable freshwater production through advanced membrane desalination technology.
With a nominal production capacity of 2 m³/h, the system provides a compact solution for professional seawater desalination and industrial water treatment applications where consistent operation, practical installation and efficient use of available space are important. The system dimensions and connection configuration are designed to support straightforward integration into new or existing water treatment installations, while dedicated inlet, permeate and concentrate connections provide the primary interfaces required for the reverse osmosis process. Separate CIP inlet, return and permeate connections support professional cleaning procedures and ongoing system maintenance, while the dedicated antiscalant dosing port enables integration of chemical dosing into the pretreatment process. With a maximum power consumption of 11,530 W, the system provides clearly defined electrical requirements for installation planning. As part of YWT’s range of industrial reverse osmosis systems, the SWRO System 2 m³/h combines a practical physical footprint with the process connections required for professional seawater treatment, reverse osmosis and industrial desalination applications.

System Components

EQUIPMENT

Danfoss high pressure pump APP 5.1: 1 pc
8040 2 membrane housing: 2 pcs
BB20 sediment prefilter: 3 pcs
Motorized valve: 1 pc
Balancing valve for concentrate reject: 1 pc
Pulsation dampener: 1 pc
Electrical panel with Unitronics PLC controller: 1 set
ABB conductivity controller: 1 set, pH option available
Danfoss pressure switches: 2 pcs
AISI 316 stainless steel high pressure line: 1 set
AISI 304 stainless steel frame: 1 set
Grundfos dosing pump: 1 set, option for 2 sets

 

 

YWT SWRO System 2 m³/h

is built with industrial grade components selected for reliable operation in demanding seawater reverse osmosis and desalination applications. The Danfoss APP 5.1 high pressure pump provides the pressure required for the membrane separation process, while the 8040 membrane housings form the core of the reverse osmosis system. BB20 sediment prefilters support feed water pretreatment, and the Grundfos dosing pump enables antiscalant dosing to support effective RO operation. Automated process management is provided by a Unitronics PLC controller, supported by ABB conductivity monitoring, Danfoss pressure switches, motorized flow control and concentrate regulation. For durability in demanding operating conditions, the high pressure line is manufactured from AISI 316 stainless steel, while the complete system is mounted on a robust AISI 304 stainless steel frame. Together, these components create a professional industrial reverse osmosis system designed for controlled operation, dependable performance and efficient seawater desalination and industrial water treatment.

Source Water Requirements

SOURCE WATER CONDITIONS

Water source: Seawater
Pretreatment: Required according to source water quality
Suspended solids: Must be controlled through appropriate pretreatment
Turbidity: Should be reduced before entering the RO membrane stage
Scaling potential: Must be evaluated and controlled
Antiscalant dosing: Supported through dedicated dosing connection
Feed water analysis: Recommended before system installation and operation
Biological contamination: Pretreatment may be required depending on source water conditions
Chemical compatibility: Feed water conditions must remain within the operating limits of the RO membranes and system components

 

 

Source water quality is a critical factor in the performance, efficiency and service life of any seawater reverse osmosis system. Before seawater enters the YWT SWRO System 2 m³/h, its physical, chemical and biological characteristics should be evaluated to determine the appropriate pretreatment and operating conditions. Parameters such as salinity, suspended solids, turbidity, scaling potential, biological activity and chemical composition can influence membrane fouling, operating pressure, permeate quality and overall desalination performance. Effective pretreatment and correct antiscalant dosing help protect the reverse osmosis membranes, high pressure equipment and other system components while supporting stable freshwater production. For professional seawater desalination and industrial water treatment, a source water analysis should therefore be used to establish the appropriate pretreatment strategy and confirm that feed water conditions are suitable for reliable operation of the industrial reverse osmosis system.

Service and Maintenance

ROUTINE SERVICE REQUIREMENTS

Sediment prefilters:

Inspect regularly and replace when differential pressure increases or when filter condition indicates reduced performance.

 

RO membranes:

Monitor permeate flow, conductivity, salt rejection and pressure. Clean the membranes when normalized performance declines and replace them when cleaning can no longer restore the required water quality or production capacity.

 

High pressure pump:

Inspect periodically for abnormal noise, vibration, leakage and changes in operating pressure. Service according to the pump manufacturer’s maintenance requirements.

 

Antiscalant dosing system:

Check chemical level and dosing operation regularly. Inspect the dosing pump, tubing and injection point to ensure accurate and continuous chemical dosing.

 

Conductivity monitoring:

Check conductivity readings routinely to verify permeate quality and identify changes in reverse osmosis performance.

 

Pressure switches and valves:

Inspect periodically for correct operation, leakage and stable process control.

 

CIP cleaning:

Perform membrane cleaning when operating data indicates fouling, scaling or a significant decline in normalized system performance.

 

Stainless steel piping and connections:

Inspect periodically for leakage, corrosion, loose fittings or other signs of wear.

 

PLC and electrical panel:

Check alarms, operating parameters, electrical connections and control functions as part of scheduled preventive maintenance.

 

Regular service and preventive maintenance are essential for maintaining the performance, reliability and operating life of the YWT SWRO System 2 m³/h. A seawater reverse osmosis system operates under demanding conditions, including high salinity and high operating pressure, making routine monitoring particularly important for the membranes, high pressure pump, pretreatment filters, chemical dosing equipment and process instrumentation. Monitoring pressure, permeate flow, conductivity and other operating parameters can help identify membrane fouling, scaling, filter blockage or changes in system performance before they develop into more significant operational problems. Correct antiscalant dosing and timely CIP membrane cleaning also help protect the reverse osmosis membranes and maintain efficient seawater desalination performance. A structured preventive maintenance program helps an industrial reverse osmosis system maintain consistent water quality, stable freshwater production and dependable operation while reducing unnecessary downtime and supporting a longer service life for critical water treatment components.

Technical information

PHYSICAL PARAMETERS:

Approximate dimensions (bare) 2.1 ×1.0 ×1.90 m

Approximate dimensions (crated) 2.30 ×1.20 ×2.0 m

(Width ×Depth ×Height, ±5%)

Approximate weight (bare) 350 kg

Approximate weight (crated) 460 kg

Maximum Power Consumption 11 530 W

EQUIPMENT

• Danfosshigh pressure pump APP 5.1 1 pcs

• 8040-2 membrane housing 2 pcs

• BB20 sediment prefilter 3 pcs

• Motorized valves 1 pcs

• Balancing valve (concentrate reject) 1 pcs

• Pulsation Dampener 1 pcs

• Electrical panel with PLC Unitronicscontroller 1 set

• ABB conductivity controller 1 set (pH option)

• Danfoss pressure switches 2 pcs

• AISI 316 Stainless-steel high-pressure line 1 set

• AISI 304 Stainless steel frame 1 set

• Grundfos dosing pump 1 set (option for 2 sets)

CONNECTION PORT SIZES:

Inlet water G 1½″

Permeate G 1½″

Concentrate G 1″

CIP inlet G 1½″

CIP return G 1½″

CIP permeate G 1½″

Antiscalant dosing port G ½″

get in touch