APPLICATIONS
Desalination units for operations requiring a reliable source of fresh water: boutique coastal hotels, eco-resorts, coastal farms, greenhouses, coastal construction site, small islands, science coastal camps
The YWT SWRO System 1 m³/h is a compact industrial seawater reverse osmosis system engineered for reliable and efficient desalination. Built with industrial grade components and automated process control, it provides consistent freshwater production for professional and industrial water treatment applications.
A stable company with extensive experience in the water industry.
We develop high-quality products at competitive prices.
Delivering advanced solutions backed by knowledge, innovation, and industry expertise.
PHYSICAL PARAMETERS
Approximate dimensions (bare): 2.1 × 1.0 × 1.90 m
Approximate dimensions (crated): 2.30 × 1.20 × 2.0 m
Dimensions: Width × Depth × Height, ±5%
Approximate weight (bare): 320 kg
Approximate weight (crated): 410 kg
Maximum Power Consumption: 11,530 W
CONNECTION PORT SIZES
Inlet water: G 1½″
Permeate: G 1½″
Concentrate: G 1″
CIP inlet: G 1½″
CIP return: G 1½″
CIP permeate: G 1½″
Antiscalant dosing port: G ½″
YWT SWRO System 1 m³/h is a compact industrial seawater reverse osmosis system designed for reliable freshwater production through membrane desalination technology. With a nominal production capacity of 1 m³/h, the system provides a practical solution for professional seawater desalination and industrial water treatment applications where space, installation requirements and dependable operation are important considerations. The system incorporates dedicated connections for feed water, treated permeate and concentrate discharge, providing the primary process interfaces required for reverse osmosis operation. Separate CIP inlet, return and permeate connections support membrane cleaning and scheduled maintenance, while the dedicated antiscalant dosing port allows chemical dosing to be integrated into the seawater treatment process. With a maximum power consumption of 11,530 W and a compact industrial footprint, the system provides clearly defined mechanical and electrical parameters for installation and engineering planning. As part of YWT’s range of industrial reverse osmosis systems, the SWRO System 1 m³/h is designed to provide a professional solution for seawater treatment, industrial desalination and applications requiring dependable on site freshwater production.
EQUIPMENT
Danfoss high pressure pump APP 3.5: 1 pc
8040 2 membrane housing: 1 pc
BB20 sediment prefilter: 3 pcs
Motorized valve: 1 pc
Balancing valve for concentrate reject: 1 pc
Pulsation dampener: 1 pc
Electrical panel with Unitronics PLC controller: 1 set
ABB conductivity controller: 1 set, pH option available
Danfoss pressure switches: 2 pcs
AISI 316 stainless steel high pressure line: 1 set
AISI 304 stainless steel frame: 1 set
Grundfos dosing pump: 1 set, option for 2 sets
YWT SWRO System 1 m³/h is built with industrial grade components selected for reliable operation in professional seawater desalination applications. The Danfoss APP 3.5 high pressure pump supplies the pressure required for the reverse osmosis membrane separation process, while the 8040 membrane housing forms the core of the RO treatment stage. Three BB20 sediment prefilters support feed water pretreatment, and the Grundfos dosing pump enables controlled antiscalant dosing to support stable system operation. Process management is handled through a Unitronics PLC controller, supported by ABB conductivity monitoring, Danfoss pressure switches, motorized flow control and concentrate regulation. The high pressure process line is manufactured from AISI 316 stainless steel, while the complete system is mounted on a robust AISI 304 stainless steel frame. Together, these components create a compact industrial reverse osmosis system designed for controlled operation, dependable seawater treatment and consistent freshwater production in professional industrial water treatment and desalination applications.
SOURCE WATER CONDITIONS
Water source: Seawater
Pretreatment: Required according to source water quality
Suspended solids: Must be controlled through appropriate pretreatment
Turbidity: Should be reduced before entering the RO membrane stage
Scaling potential: Must be evaluated and controlled
Antiscalant dosing: Required according to feed water composition and operating conditions
Feed water analysis: Recommended before installation and commissioning
Biological contamination: Pretreatment may be required depending on source water conditions
Chemical compatibility: Feed water must remain within the operating limits of the RO membranes and system components
Source water quality is a critical factor in the performance, efficiency and operating life of the YWT SWRO System 1 m³/h. Before seawater enters the reverse osmosis system, its physical, chemical and biological characteristics should be evaluated to establish the appropriate pretreatment and chemical dosing requirements. Factors such as salinity, suspended solids, turbidity, scaling potential, biological activity and overall water chemistry can directly influence membrane fouling, operating pressure, salt rejection and permeate quality. Effective pretreatment and correct antiscalant dosing help protect the reverse osmosis membranes, high pressure pump and other critical components while supporting stable freshwater production. A professional feed water analysis is therefore recommended before commissioning the seawater reverse osmosis system, allowing suitable operating conditions and pretreatment processes to be established for reliable seawater desalination and industrial water treatment.
ROUTINE SERVICE REQUIREMENTS
Sediment prefilters:
Inspect regularly and replace when differential pressure increases or filter condition indicates reduced flow or performance.
RO membranes:
Monitor permeate flow, conductivity, salt rejection and operating pressure. Clean the membranes when normalized performance declines and replace them when cleaning can no longer restore the required water quality or production capacity.
High pressure pump:
Inspect periodically for leakage, abnormal noise, vibration and changes in operating pressure. Service according to the pump manufacturer’s maintenance requirements.
Antiscalant dosing system:
Check chemical levels, dosing rate, tubing and injection points regularly to maintain accurate and continuous dosing.
Conductivity monitoring:
Check conductivity readings routinely to verify permeate quality and identify changes in reverse osmosis performance.
Pressure switches and valves:
Inspect periodically for correct operation, stable pressure control and leakage.
CIP membrane cleaning:
Perform cleaning when operating data indicates membrane fouling, scaling or a significant decline in normalized flow or salt rejection.
Stainless steel piping and connections:
Inspect periodically for leakage, corrosion, loose fittings and signs of mechanical wear.
PLC and electrical panel:
Check system alarms, operating parameters, control functions and electrical connections as part of scheduled preventive maintenance.
Regular service and preventive maintenance are essential for maintaining the efficiency, reliability and operating life of the YWT SWRO System 1 m³/h. Seawater reverse osmosis systems operate under demanding conditions involving high salinity and elevated pressure, making routine monitoring of the membranes, high pressure pump, prefilters, dosing equipment and process instrumentation particularly important. Monitoring operating pressure, permeate flow, conductivity and salt rejection can help identify membrane fouling, scaling, filter blockage or other changes in performance before they lead to significant production losses. Correct antiscalant dosing and timely CIP membrane cleaning help maintain membrane efficiency and consistent freshwater production. A structured preventive maintenance program supports reliable operation of the industrial reverse osmosis system, helps maintain the required permeate quality and reduces unnecessary downtime while extending the service life of critical seawater desalination equipment.
PHYSICAL PARAMETERS:
Approximate dimensions (bare) 2.1 ×1.0 ×1.90 m
Approximate dimensions (crated) 2.30 ×1.20 ×2.0 m
(Width ×Depth ×Height, ±5%)
Approximate weight (bare) 320kg
Approximate weight (crated) 410 kg
Maximum Power Consumption 11 530 W
EQUIPMENT
• Danfoss high pressure pump APP 3.5 1 pcs
• 8040-2 membrane housing 1 pcs
• BB20 sediment prefilter 3 pcs
• Motorized valves 1 pcs
• Balancing valve (concentrate reject) 1 pcs
• Pulsation Dampener 1 pcs
• Electrical panel with PLC Unitronicscontroller 1 set
• ABB conductivity controller 1 set (pH option)
• Danfoss pressure switches 2 pcs
• AISI 316 Stainless-steel high-pressure line 1 set
• AISI 304 Stainless steel frame 1 set
• Grundfos dosing pump 1 set (option for 2 sets)
CONNECTION PORT SIZES:
Inlet water G 1½″
Permeate G 1½″
Concentrate G 1″
CIP inlet G 1½″
CIP return G 1½″
CIP permeate G 1½″
Antiscalant dosing port G ½″